SSI response of a typical shear wall structure. Appendix B. In-structure response spectra comparisons. Volume 2

Description

The objectives of this study were two-fold: (1) develop building response calibration factors, i.e., factors which relate best estimate or median level response to responses calculated by selected design procedures. Soil-structure interaction was the phenomenon of interest because significant simplifications are frequently introduced in its treatment; and (2) the second objective can be viewed in the context of a question: what effect does placing an identical structure on different sites and with different foundation conditions have on structure response. The structure selected for this study is a part of the Zion AFT complex. Only the auxiliary, fuel-handling, and diesel generator buildings were studied. This structure is a connected group of shear-wall buildings constructed of reinforced concrete, typical of nuclear power plant structures. The bases of comparison for this study were structure responses: peak in-structure accelerations (27 components), and peak wall forces and moments (111 components). In-structure response spectra were also considered. This appendix contains in-structure response spectra comparisons in detail

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A99/MF A01; 1 as DE84017441.

Files

16027208.pdf

Files (6.0 MB)

Name Size Download all
md5:5b3971dfe168743803d2cb67676817f8
6.0 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
791 p.
Report number
UCID--20122-Vol.2

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16027208
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
BUILDINGS; NUCLEAR POWER PLANTS; SEISMIC EFFECTS; SOIL-STRUCTURE INTERACTIONS; SPECTRA
Descriptors DEC
NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS