Published March 1999 | Version v1
Journal article

A linear Paul trap for radiative lifetime measurements on ions

  • 1. Hannover Univ. (Germany). Inst. fuer Atom- und Molekuelphysik

Description

A linear ion trap has been designed for collimation and storage of ions from an effusive particle beam generated in a hollow cathode discharge. The motivation is to measure radiative lifetimes on multiply ionized atoms by using the time-resolved laser-induced fluorescence technique. The trap has been tested on iron and tungsten ions both as an ion guide and also as a storing device. Radiative lifetimes have been measured in the trap with a remarkably higher signal-to-noise ratio than in the original effusive atom beam. (orig.)

Additional details

Publishing Information

Journal Title
European Physical Journal. D, Atomic, Molecular and Optical
Journal Volume
5
Journal Issue
3
Journal Page Range
p. 341-344
ISSN
1434-6060

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
30015568
Subject category
S74: ATOMIC AND MOLECULAR PHYSICS; S74: ATOMIC AND MOLECULAR PHYSICS;
Descriptors DEI
CATIONS; FLUORESCENCE; IRON; RADIATIVE DECAY; TRAPPING; TUNGSTEN
Descriptors DEC
CHARGED PARTICLES; DECAY; ELEMENTS; EMISSION; IONS; LUMINESCENCE; METALS; PARTICLE DECAY; PHOTON EMISSION; TRANSITION ELEMENTS

Optional Information

Notes
22 refs.