Published January 2017 | Version v1
Journal article

BESⅢ ETOF upgrade readout electronics commissioning

  • 1. Institute of High Energy Physics, Chinese Academy of Sciences, Beijing (China)
  • 2. State Key Laboratory of Particle Detection and Electronics, Beijing (China)
  • 3. Department of Modern Physics, University of Science and Technology of China, Hefei (China)

Description

It is proposed to upgrade the endcap time-of-flight (ETOF) of the Beijing Spectrometer Ⅲ(BESⅢ) with a multi-gap resistive plate chamber (MRPC), aiming at an overall time resolution of about 80 ps. After completing the entire readout electronics system, some experiments, such as heat radiation, radiation hardness and large-current beam tests, have been carried out to confirm the reliability and stability of the readout electronics. An on-detector test of the readout electronics has also been performed with the beam at the BEPCⅡ E3 line. The test results indicate that the readout electronics system fulfills its design requirements. (authors)

Additional details

Publishing Information

Journal Title
Chinese Physics. C, High Energy Physics and Nuclear Physics
Journal Volume
41
Journal Issue
1
Journal Page Range
[6 p.]
ISSN
1674-1137

Optional Information

Notes
14 figs., 14 refs.; http://dx.doi.org/10.1088/1674-1137/41/1/016103