Published January 1986 | Version v1
Journal article

Neutron flux stabilization in the NG-150 neutron generators

Description

Problem of metal tritium target lifetime increase and neutron flux stabilization in the NG-150 neutron generators is studied. Possibility on neutron flux stabilization using the mass analyzer for low-angle (4 deg and 41 deg) mass separation of a beam in thre components, which fall on a target simultaneously, is confirmed experimentally. Basic generator parameters are: accelerating voltage of 150 kV, total beam current on a target of 1.5 mA, beam current density of 0.3-1.6 mA/cm2, beam diameter of 8 mm. The initial neutron flux on the targets of 0.73 mg/cm2 thick constituted 1.1x1011 ssup(-1). The neutron flux monitoring was accomplished from recoil proton recording by a plastic scintillator. Flux decrease by more than 5% served as a signel for measuring mass analyzer magnetic field providing beam displacement on a target and restoration of the given flux. The NG-150 generator neutron flux stabilization was attained during 2h

Additional details

Additional titles

Original title (Russian)
Стабилизация потока нейтронов в нейтронных генераторах NG-150

Publishing Information

Journal Title
At. Ehnerg.
Journal Volume
60
Journal Issue
1
Series
At. Ehnerg.
Journal Page Range
67-68
ISSN
0004-7163
CODEN
AENGA

Optional Information

Notes
For English translation see the journal Soviet Journal of Atomic Energy (USA).