Published March 2017
| Version v1
Journal article
Relative power calibration on critical facility through neutron activation method
- 1. Reactor Engineering Research Division, Nuclear Power Institute of China, Chengdu (China)
Description
The paper introduces relative power calibration on the critical facility through neutron activation method. The operational power limit can be calibrated through this method. MCNP calculation is checked by the experimental results of power calibration. Average neutron flux density under limit can be deduced from the calculation results. This is very important for the safe operation of reactors. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 37
- Journal Issue
- 3
- Journal Page Range
- p. 319-322
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 53032724
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CALIBRATION; FLUX DENSITY; NEUTRON FLUX; NEUTRONS; POWER; WATER MODERATED REACTORS; ZERO POWER REACTORS
- Descriptors DEC
- BARYONS; ELEMENTARY PARTICLES; EXPERIMENTAL REACTORS; FERMIONS; HADRONS; NUCLEONS; RADIATION FLUX; REACTORS; RESEARCH AND TEST REACTORS
Optional Information
- Notes
- 4 figs., 2 tabs., 3 refs.