Published July 1991 | Version v1
Journal article

Method of frequency stabilization with a cavity for the feedback linac

  • 1. Nanjing Univ., JS (China). Dept. of Physics

Description

An improved method of frequency stabilization with the resonance cavity was described. The change of signal area was more suitable than the change of signal amplitude to show the deviation of the oscillation frequency of the magnetron from the resonance frequency of the cavity. The output of the detector could by integrated to find the signal area which was converted into data by an ADC and be transferred into the single chip processor and processed. The output of the microprocessor could control the servo to tune the magnetron. As a result, the change of oscillation frequency of the magnetron would be controlled with in ±20 KHz

Additional details

Publishing Information

Journal Title
Journal of Nanjing University, Natural Sciences Edition
Journal Volume
27
Journal Issue
3
Series
J. Nanjing Univ., Nat. Sci. Ed.
Journal Page Range
443-448
ISSN
0465-7926
CODEN
NCHPA