Published April 1976
| Version v1
Report
Open
SLIFER measurement for explosive yield
Description
This report describes the shorted location indicator by frequency of electrical resonance (SLIFER) system used at Sandia Laboratories for determination of explosive yield of under ground nuclear tests
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS.Files
7268864.pdf
Files
(1.5 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:1d109e018248127555a4fd809827cd89
|
1.5 MB | Preview Download |
Additional details
Additional titles
- Augmented title (English)
- Shorted Location Indicator by Frequency of Electrical Resonance (SLIFER)
Publishing Information
- Imprint Pagination
- 99 p.
- Report number
- SAND--76-0007
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 7268864
- Subject category
- S42: ENGINEERING; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- DIAGRAMS; ELECTRONIC CIRCUITS; FISSION YIELD; MEASURING INSTRUMENTS; NUCLEAR EXPLOSIONS; UNDERGROUND EXPLOSIONS
- Descriptors DEC
- EXPLOSIONS; NUCLEAR REACTION YIELD
Optional Information
- Notes
- Available from NTIS. $5.50.