Published April 1976 | Version v1
Report Open

SLIFER measurement for explosive yield

Description

This report describes the shorted location indicator by frequency of electrical resonance (SLIFER) system used at Sandia Laboratories for determination of explosive yield of under ground nuclear tests

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS.

Files

7268864.pdf

Files (1.5 MB)

Name Size Download all
md5:1d109e018248127555a4fd809827cd89
1.5 MB Preview Download

Additional details

Additional titles

Augmented title (English)
Shorted Location Indicator by Frequency of Electrical Resonance (SLIFER)

Publishing Information

Imprint Pagination
99 p.
Report number
SAND--76-0007

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
7268864
Subject category
S42: ENGINEERING; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
DIAGRAMS; ELECTRONIC CIRCUITS; FISSION YIELD; MEASURING INSTRUMENTS; NUCLEAR EXPLOSIONS; UNDERGROUND EXPLOSIONS
Descriptors DEC
EXPLOSIONS; NUCLEAR REACTION YIELD

Optional Information

Notes
Available from NTIS. $5.50.