Published 1983 | Version v1
Journal article

Plant design and beam utilization

  • 1. Radest A/S, Glostrup (Denmark)

Description

Plant design and beam utilization are two things closely tied together: without a proper plant design, one can never get good beam utilization. When a company decides to build an irradiation facility, there are some major decisions to be made right in the beginning. These decisions can be most important for the long-term success or failure of the irradiation facility, because the company normally will have to live with these decisions during the whole life-time of the irradiation equipment. To start with the decision has to be made whether to select a cobalt-60 irradiation plant or an accelerator irradiation plant. This decision can only be reached after a careful study of the products and the 'weight' and the material of the products the company wants to irradiate. As an old accelerator-man, I tend to personally favor accelerators, although I am very impressed by the newer cobalt-60 pallet irradiation plants from A.E.C.L. I believe that they have a great future in the emerging field of food irradiation. As I have primarily been involved with accelerators during the last 14 years, this paper is only dealing with different design approaches and utilizations of accelerator-plants. (author)

Additional details

Publishing Information

Journal Title
Radiat. Phys. Chem.
Journal Issue
v.22(1-2
Series
Radiat. Phys. Chem.
ISSN
0146-5724

Conference

Title
4. international meeting on radiation processing.
Dates
4-8 Oct 1982.
Place
Dubrovnik (Yugoslavia).