Purpose: To assess the role of three-dimensional volume rendering (3DVR) in the preoperative assessment of the ossicular chain in chronic suppurative otitis media (CSOM). Materials and methods: Sixty-six patients with CSOM were included in this prospective study. Temporal bone was scanned with a 128-channel multidetector row CT and the axial data was transferred to the workstation for multiplanar reformation (MPR) and 3DVR reconstructions. Evaluation of the ossicular chain according to a three-point scoring system on two-dimensional reformation (2D) and 3DVR was performed independently by two radiologists. The evaluation results were compared with surgical findings. Results: 2D showed over 89% accuracy in the assessment of segmental absence of the ossicular chain in CSOM, no matter how small the segmental size was. 3DVR was as accurate as 2D for the assessment of segmental absence. However, 3DVR was found to be more accurate than 2D in the evaluation of partial erosion of segments. Conclusion: Both 3DVR and 2D are accurate and reliable for the assessment of the ossicular chain in CSOM. The inclusion of 3DVR images in the imaging protocol improves the accuracy of 2D in detecting ossicular erosion from CSOM
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2013.03.010Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2013.03.010;
- PII
- S0720-048X(13)00156-3;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 82
- Journal Issue
- 9
- Journal Page Range
- p. 1519-1524
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Cuba
- INIS RN
- 47016017
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; COMPARATIVE EVALUATIONS; IMAGES; INCLUSIONS; PATIENTS; SKELETON; SURGERY; THREE-DIMENSIONAL LATTICES; TWO-DIMENSIONAL SYSTEMS
- Descriptors DEC
- BODY; CRYSTAL LATTICES; CRYSTAL STRUCTURE; EVALUATION; MEDICINE; ORGANS
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.