Experimental study for the production cross sections of positron emitters induced from 12C and 16O nuclei by low-energy proton beams
Creators
- 1. Department of Radiation Physics, Hyogo Ion Beam Medical Center, 1-2-1 Kouto Shingu-cho, Tatsuno City, Hyogo 679-5165 (Japan)
- 2. Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamadao-ka, Suita City, Osaka 566-0871 (Japan)
- 3. Department of Radiation Oncology, Hyogo Ion Beam Medical Center, 1-2-1 Kouto Shingu-cho, Tatsuno City, Hyogo 679-5165 (Japan)
- 4. Research and Development Department, Medical Systems Division, Shimadzu Corporation, 1 Nishinokyo-kuwabaracho, Nakagyo-ku, Kyoto 604-8511 (Japan)
- 5. Photo Medical Research Center, Japan Atomic Energy Agency, 8-1 Umemidai Kizugawa City, Kyoto 619-0215 (Japan)
Description
In proton therapy, positron emitters are induced from 12C and 16O nuclei by protons on the beam path in the patient. Many studies for monitoring positron emitters with beam-induced PET technique have been performed by various groups to verify the proton beam range and the dose in the patient for quality assurance (QA). The QA methods proposed by some groups require accurate production cross sections of the positron emitters produced by protons, especially in the low-energy region. The aim of this study was to develop a method for measuring the production cross sections of positron emitters using standard equipment for proton therapy, and to measure the cross sections of positron emitters produced by low-energy protons and verify them in comparison with data of previous experiments. An 80-MeV proton beam was produced by a synchrotron, and the energy was degraded by polyethylene blocks to obtain various beam energies. The number of protons was estimated from the charge induced in a parallel-plate ionization chamber by protons. Low-energy protons of 14–70 MeV were used to bombard 12C-rich and 16O-rich target materials: namely, polyethylene and gelatinous water. The time-activity curve was then measured by a high-sensitivity PET scanner to extract the number of positron emitters produced in the target. The production cross sections for four reaction channels: 16O(p, pn)15O, 16O(p, 3p3n)11C, 16O(p, 2p2n)13N, and 12C(p, pn)11C were then measured. The cross sections for the 16O(p, pn)15O reaction channel were consistent with data of previous experiments within the uncertainties, while those of 12C(p, pn)11C were generally lower than data of previous experiments. These results suggested that further measurements of the production cross sections will be necessary. -- Highlights: • We measure the production cross sections of positron emitters induced by protons. • Reaction channels: 16O(p, pn)15O, 16O(p, 3p3n)11C, 16O(p, 2p2n)13N, 12C(p, pn)11C. • The measurements for 16O were generally consistent with past experimental data. • The measurements for 12C were generally lower than past experimental data
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radmeas.2013.07.005Additional details
Identifiers
- DOI
- 10.1016/j.radmeas.2013.07.005;
- PII
- S1350-4487(13)00286-2;
Publishing Information
- Journal Title
- Radiation Measurements
- Journal Volume
- 59
- Journal Page Range
- p. 262-269
- ISSN
- 1350-4487
- CODEN
- RMEAEP
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45096034
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- CARBON 11; CARBON 12; CROSS SECTIONS; IONIZATION CHAMBERS; NITROGEN 13; OXYGEN 15; OXYGEN 16; POSITRONS; PROTON BEAMS; QUALITY ASSURANCE; RADIOTHERAPY
- Descriptors DEC
- ANTILEPTONS; ANTIMATTER; ANTIPARTICLES; BEAMS; BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; CARBON ISOTOPES; ELECTRON CAPTURE RADIOISOTOPES; ELEMENTARY PARTICLES; EVEN-EVEN NUCLEI; EVEN-ODD NUCLEI; FERMIONS; ISOTOPES; LEPTONS; LIGHT NUCLEI; MATTER; MEASURING INSTRUMENTS; MEDICINE; MINUTES LIVING RADIOISOTOPES; NITROGEN ISOTOPES; NUCLEAR MEDICINE; NUCLEI; NUCLEON BEAMS; ODD-EVEN NUCLEI; OXYGEN ISOTOPES; PARTICLE BEAMS; RADIATION DETECTORS; RADIOISOTOPES; RADIOLOGY; STABLE ISOTOPES; THERAPY
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.