Toward the clinical application of the prompt gamma-ray timing method for range verification in proton therapy
Description
The prompt gamma-ray timing (PGT) method offers a relatively simple approach for range verification in proton therapy. Starting from the findings of previous experiments, several steps toward a clinical application of PGT have been performed in this work. First of all, several scintillation materials have been investigated in the context of PGT. The time resolution was determined at high photon energies in the MeV-region. In conclusion, the fast and bright scintillator CeBr3 is the material of choice in combination with a timing photomultiplier tube as light detector. A second study was conducted at Universitaets Protonen Therapie Dresden (UPTD) to characterize the proton bunch structure of a clinical beam concerning its time width and relative arrival time. The data is mandatory as input for simulation studies and to correct for phase drifts. The obtained data could furthermore be used for the first 2D imaging of a heterogeneous phantom based on prompt gamma-rays. In a last step, a PGT prototype system was designed using the findings from the first two studies. The prototype system is based on a newly developed digital spectrometer and a CeBr3 detector. The device is characterized at the ELBE bremsstrahlung beam. It was verified that the prototype operates within the specifications concerning time and resolution as well as throughput rate. Finally, for the first time the PGT system was used under clinical conditions in the treatment room of UPTD. Here, PGT data was obtained from the delivery of a three-dimensional treatment plan onto PMMA phantoms. The spot-by-spot analysis helped to investigate the performance of the prototype device under clinical conditions. As a result, range variations of 5 mm could be detected for the first time with an uncollimated system at clinically relevant doses. To summarize, the obtained results help to bring PGT closer to a clinical application.
Files
49055542.pdf
Files
(16.9 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:9963d7c231ac1c90c968b69ec500e30d
|
16.9 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 162 p.
- Report number
- INIS-DE--2231
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 49055542
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Thesis
- Descriptors DEI
- ATTENUATION; BREMSSTRAHLUNG; CALCIUM BROMIDES; CLINICAL TRIALS; DEPTH DOSE DISTRIBUTIONS; GAMMA SPECTROSCOPY; IN VIVO; MEV RANGE; PHANTOMS; PHOTOMULTIPLIERS; PMMA; POSITRON COMPUTED TOMOGRAPHY; PROMPT GAMMA RADIATION; PROTON BEAMS; RADIOTHERAPY; SOLID SCINTILLATION DETECTORS; TIME RESOLUTION; VERIFICATION
- Descriptors DEC
- ALKALINE EARTH METAL COMPOUNDS; BEAMS; BROMIDES; BROMINE COMPOUNDS; CALCIUM COMPOUNDS; CALCIUM HALIDES; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; EMISSION COMPUTED TOMOGRAPHY; ENERGY RANGE; ESTERS; GAMMA RADIATION; HALIDES; HALOGEN COMPOUNDS; IONIZING RADIATIONS; MEASURING INSTRUMENTS; MEDICINE; MOCKUP; NUCLEAR MEDICINE; NUCLEON BEAMS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; PARTICLE BEAMS; PHOTOTUBES; POLYACRYLATES; POLYMERS; POLYVINYLS; RADIATION DETECTORS; RADIATION DOSE DISTRIBUTIONS; RADIATIONS; RADIOLOGY; RESOLUTION; SCINTILLATION COUNTERS; SPATIAL DOSE DISTRIBUTIONS; SPECTROSCOPY; STRUCTURAL MODELS; TESTING; THERAPY; TIMING PROPERTIES; TOMOGRAPHY