Published 1995 | Version v1
Report

Severe Accident Management Simplified

  • 1. Westinghouse Electric Corp., Nuclear Technology Division, P.O. Box 355, Pittsburgh, Pennsylvania 15230 (United States)

Description

After having recalled in which context the Severe Accident Management Guidance (SAMG) was developed by the Westinghouse Owners Group, the authors present its reference decision-making process which includes the following levels: diagnose plant conditions, prioritize response, assess equipment availability, identify and assess negative impacts, determine whether to implement available equipment, determine whether implemented actions are effective, identify long term concerns for implemented strategies. They indicate the goals that would form the foundation of this guidance (a set of three primary goals and two secondary goals concerning the release of radioactivity, the containment of fission products, and the return to stable conditions). Then, they indicate how the number of fundamental status parameters has been reduced to six with the corresponding actions

Part of:
Proceedings of the specialist meeting on severe accident management implementation

Additional details

Publishing Information

Imprint Title
Proceedings of the specialist meeting on severe accident management implementation
Imprint Pagination
541 p.
Journal Page Range
p. 125-130
Report number
NEA-CSNI-R--1995-5

Conference

Title
Specialist meeting on severe accident management implementation
Dates
12-14 Jun 1995
Place
Niantic, CT (United States)

Optional Information