Published 2021 | Version v1
Book

MCP with delay-line anode used for position sensitive detector at Rare RI Ring

  • 1. RIKEN Nishina Center for Accelerator-Based Science, Wako, Saitama (Japan)

Description

The Rare RI Ring (R3) aims at measuring masses of exotic nuclei with precision of 10−6. In order to achieve this goal, the beam diagnostics is needed at the beam line to improve the transport efficiency and measure the velocity of nuclei of interest. For this purpose, we are developing position sensitive detectors with lower energy loss than conventional beam line detectors. We report the development of the foil position sensitive detector based on micro-channel plates (MCPs) with a delay-line anode. (author)

Availability note (English)

Available from DOI: https://doi.org/10.7566/JPSCP.35.011025
Part of:
Proceedings of 10th International Conference on Nuclear Physics at Storage Rings (STORI'17)

Additional details

Identifiers

Publishing Information

Publisher
Physical Society of Japan
Imprint Place
Tokyo (Japan)
ISBN
978-4-89027-148-1
Imprint Title
Proceedings of 10th International Conference on Nuclear Physics at Storage Rings (STORI#Right Single Quotation Mark#17)
Imprint Pagination
[171 p.]
Journal Page Range
p. 011025.1-011025.4

Conference

Title
10. international conference on nuclear physics at storage rings
Acronym
STORI'17
Dates
13-18 Nov 2017
Place
Kanazawa, Ishikawa (Japan)

Optional Information

Notes
5 refs., 3 figs.