Published October 1, 2011 | Version v1
Journal article

Nano-scopic measurement for radiation of nuclear waste forms using ion beam injection in the drum treatment

  • 1. Department of Advanced Technology, Korea Research and Simulation and Corporation, Seoul 136-780 (Korea, Republic of)
  • 2. Department of Radiological Science, College of Health Science, Yonsei University, Wonju 220-710 (Korea, Republic of)

Description

The irradiation-induced nuclear waste material has been investigated. Alpha particles are considered as the waste radiation. The material aspects are considered for four kinds of materials, which are used for the nuclear waste forms. These materials are compared for the possibility of the irradiation-induced amorphization. Several variables are investigated for the ion radiation interactions. We have used the Stopping and Range of Ion in Matter 2008 (SRIM 2008) code system to show that the ion dose is changed to the displacement per atom (dpa) completely and the kinetic energy is transferred to each target atom through nuclear collision. The necessary thickness of the waste form has been investigated. More reasonable study has been done for the nuclear waste material container. The thickness of 204 nm is considered for the optimized structure of waste drum by crystalline silicotitanate.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2010.09.104

Additional details

Identifiers

DOI
10.1016/j.nima.2010.09.104;
PII
S0168-9002(10)02137-6;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
652
Journal Issue
1
Journal Page Range
p. 69-72
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
12. Symposium on radiation measurements and applications (SORMA)
Dates
24-28 May 2010
Place
Ann Arbor, MI (United States)

Optional Information

Copyright