Published 2000 | Version v1
Miscellaneous

Comparison of gated SPECT images in 90 .deg. C versus 76 .deg. C dual-head system with variable angle detector

  • 1. College of Medicine, Yeungnam Univ., Taegu (Korea, Republic of)

Description

Recently 76 degress with 204 degrees rotation gated SPECT were used with variable angle detector. We have compared 90 degrees with 180 degrees gantry rotation and 76 degrees with 204 degrees rotation gated SPECT images. Twenty patients in stable conditions (M/F=11/9, mean age 54) underwent two MIBI SPECT studies, one with 90 degrees and the other with 76 degrees in the same day. We used dual head system with variable angle detector. (E.CAM: Siemens, USA). Nine patients showed abnormal findings on SPECT images and 11 patients showed normal findings. Automatic quantitation of LVEFs were obtained using previously developed software and visual scoring of motion and thickening was performed using four-point scales in the same 18 segments. Segmental tracer uptake was also evaluated with visual scoring system on 18 segments. The quality of 90 degrees gated MIBI images was ranked as excellent. good, fair and poor in 5%, 75%, 20% and 0%, respectively, compared to 10%, 75%, 15%, 0%. respectively, for 76 degreees gated images. Quantitative-gated MIBI LVEFs with 90 degrees were 40.1% and 41.9% with 76 degrees and there was no significant statistical differences between the two tests. There was exact agreement of visual grading in 331 of 360 segments (92%: tau b=0.837, p<0.01) in 20 patients and 142 of 162 segments (88%: tau b=0.892, p<0.01) in ischemic patients. Exact agreement between 90 degrees and 76 degrees gated MIBI segmental myocardial function in 20 patients was 92% (tau b=0.838) and 91% for motion and thickening socres, respectively. In ischemic patients it was 86% (tau b=0.857) and 83% (tau b=0.873). Although the quality of 76 degrees images were slightly better than the 90 degrees, the tracer uptake wall thickening wall motion and LVEFS were comparable between the two tests

Part of:
Proceedings of the Korean Society Nuclear Medicine Autumn Meeting 2000

Additional details

Publishing Information

Publisher
KSNM
Imprint Place
Seoul (Korea, Republic of)
Imprint Title
Proceedings of the Korean Society Nuclear Medicine Autumn Meeting 2000
Imprint Pagination
[360 p.]
Journal Page Range
[7 p.]

Conference

Title
39. Annual Autumn Meeting of the Korean Society Nuclear Medicine
Dates
18 Nov 2000
Place
Seoul (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
33065955
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
COMPARATIVE EVALUATIONS; IMAGES; PATIENTS; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; UPTAKE
Descriptors DEC
COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; EVALUATION; TOMOGRAPHY

Optional Information

Notes
Refs.