Application of PSA level 1 for assessment of modernization program measures for Kozloduy NPP units 3 and 4

  • 1. Risk Engineering Ltd., Sofia (Bulgaria)

Description

The first PSA for the units 3 and 4 of the Kozloduy NPP has started in 1997. After the introduction of the auxiliary emergency feed water system in 1999 the PSA has been updated. In 2001 upgrading of the model is performed in in order to reflect changes in the emergency power supply systems. In order to development of the modernization program of the units 3 and 4 in 2002, an actualization of the PSA for thr inclusion of all measure, considered in the program as well as the introduction of symptom oriented emergency instructions. This actualization is to reflect the operational experience from Bulgarian reactors as well as of similar reactors in other countries

Availability note (English)

Available from INIS in electronic form

Files

33070667.pdf

Files (233.6 kB)

Name Size Download all
md5:f2f280432b8811ab5b97044271db4547
233.6 kB Preview Download

Additional details

Additional titles

Original title (Bulgarian)
Osnovni rezultati ot veroyatnosten analiz na bezopasnostta nivo 1 za 3 i 4 blokove na AETs 'Kozlouj'

Publishing Information

Imprint Pagination
6 p.
Report number
INIS-BG--0417

Conference

Title
Options, Challenges and Future'
Acronym
International Nuclear Forum 'Nuclear Power in Eastern Europe
Dates
28-30 Jun 2002
Place
Varna (Bulgaria)

Optional Information

Notes
7 figs.