Published December 2014
| Version v1
Journal article
Calculation of spent fuel pool severe accident with MELCOR
Creators
- 1. Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu (China)
- 2. Nuclear and Radiation Safety Center, Ministry of Environmental Protection, Beijing (China)
Description
A calculation model was established for spent fuel pool (SFP) using MELCOR code to study the severe accident phenomena caused by the long term station black-out (SBO), including spent fuel heatup, zirconium cladding oxidation, and the injection into SFP to mitigate the severe accident. The results show that the severe accident progression is slow and relates directly with the initial water level in SFP. It is illustrated that the injection into SFP is one of the best mitigated measures for the SFP severe accident. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 48
- Journal Issue
- 12
- Journal Page Range
- p. 2287-2291
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 48088735
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COMPUTER CALCULATIONS; DESIGN-BASIS ACCIDENTS; FUEL CANS; FUEL STORAGE POOLS; LEVELS; M CODES; OXIDATION; SPENT FUELS; WATER; ZIRCONIUM
- Descriptors DEC
- ACCIDENTS; CHEMICAL REACTIONS; COMPUTER CODES; ELEMENTS; ENERGY SOURCES; FUELS; HYDROGEN COMPOUNDS; MATERIALS; METALS; NUCLEAR FUELS; OXYGEN COMPOUNDS; REACTOR MATERIALS; TRANSITION ELEMENTS
Optional Information
- Notes
- 6 figs., 2 tabs., 9 refs.; http://dx.doi.org/10.7538/yzk.2014.48.12.2287