Published December 2014 | Version v1
Journal article

Calculation of spent fuel pool severe accident with MELCOR

  • 1. Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu (China)
  • 2. Nuclear and Radiation Safety Center, Ministry of Environmental Protection, Beijing (China)

Description

A calculation model was established for spent fuel pool (SFP) using MELCOR code to study the severe accident phenomena caused by the long term station black-out (SBO), including spent fuel heatup, zirconium cladding oxidation, and the injection into SFP to mitigate the severe accident. The results show that the severe accident progression is slow and relates directly with the initial water level in SFP. It is illustrated that the injection into SFP is one of the best mitigated measures for the SFP severe accident. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
48
Journal Issue
12
Journal Page Range
p. 2287-2291
ISSN
1000-6931

Optional Information

Notes
6 figs., 2 tabs., 9 refs.; http://dx.doi.org/10.7538/yzk.2014.48.12.2287