Published November 1998 | Version v1
Report

Study of the sensitivity of behavior of the WWER-1000 reactor to the debris size parameter during a severe accident, when using the MELCOR core

Description

The sensitivity of the WWER-1000 reactor was examined for the evolution of an accident of the 'transient with blackout' type when analyzed by the MELCOR ver. 1.8.3 code. The sensitivity on the timing of the major events when altering the size of the equivalent diameter of the debris and the effect on the course of the zirconium and steel oxidation processes were investigated

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic; e-mail contact: ret@nri.cz

Additional details

Additional titles

Original title (Czech)
Citlivostni studie chovani reaktoru WWER-1000 pri tezke havarii na zmeny parametru velikosti trosky v kodu MELCOR

Publishing Information

Imprint Pagination
[97 p.]
Report number
UJV--11167-T

Optional Information

Notes
2 tabs., 70 figs., 5 refs.