Published January 2010 | Version v1
Journal article

Design and empirical investigation of capacitive human detectors with opened electrodes

  • 1. Magallanes University, Avenida Bulnes 01855, Punta Arenas (Chile)
  • 2. Delft University of Technology, Mekelweg 4, 2628 CD Delft (Netherlands)

Description

In this paper capacitive human detectors using the novel concept of so-called 'opened electrodes' are introduced. These types of detectors have been designed for interactive art application in normal living environments where the electrodes can be integrated, for instance, into the walls, floor and ceiling. Three different examples of these detectors are presented. In all of these detectors the human body acts as a moving electrode that modifies some capacitances in the detector system. The presence and position of a person within the range of 2 m have been detected using perpendicular electrodes. In addition, a tracking area of 2 m × 2 m has been achieved using uniplanar electrodes. The sensitivity of these detectors for the estimation of a person's position has experimentally been investigated and analyzed using simple intuitive circuit models. These models are required in order to develop calibration methods and measurement techniques that reduce the effects of the main parasitic capacitances, and improve the estimation of the person's position

Availability note (English)

Available from http://dx.doi.org/10.1088/0957-0233/21/1/015802

Additional details

Identifiers

DOI
10.1088/0957-0233/21/1/015802;
PII
S0957-0233(10)12269-3;

Publishing Information

Journal Title
Measurement Science and Technology
Journal Volume
21
Journal Issue
1
Journal Page Range
[8 p.]
ISSN
0957-0233
CODEN
MSTCEP

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45005518
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CALIBRATION; DESIGN; ELECTRODES; HUMAN POPULATIONS; SENSITIVITY
Descriptors DEC
POPULATIONS