Published December 9, 1975
| Version v1
Report
Restricted
Status report on anticipated transients without scram for General Electric Reactors
Description
The review of the GE ATWS analyses included the anticipated transients expected to occur, the initial conditions and system parameter assumed in the analyses, the reliability of systems, the analytical techniques, the results of analyses of ATWS events and the design of the Reactor Protection System. Using the requirements of WASH-1270 as a guideline, the staff reviewed each relevant aspect of the GE model and analysis. The discussion of anticipated transients is presented, and the initial conditions, system parameters and operating systems assumed in the analyses of these transients are also discussed. The analytical techniques and computer programs are reviewed
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Publishing Information
- Imprint Pagination
- v p.
- Report number
- NP--21115
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8290265
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ATWS; BWR TYPE REACTORS; GE STANDARD REACTOR; MATHEMATICAL MODELS; REACTOR PROTECTION SYSTEMS; REACTOR SAFETY
- Descriptors DEC
- ACCIDENTS; DESIGN BASIS ACCIDENTS; ENRICHED URANIUM REACTORS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; SAFETY; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- Detroit Edison Co.,Mi.