Published October 1992 | Version v1
Report Open

Early detection of coolant boiling in research reactors with MTR-type fuel

  • 1. Netherlands Energy Research Foundation (ECN), Petten (Netherlands)

Description

A reactor core monitoring system having the function of early detection of boiling in the coolant channels of research reactors with MTR-type fuel is introduced. The system is based on the on-line analysis of signals of various ex-core and in-core neutron detectors. Early detection of coolant boiling cannot be accomplished by the evaluation of the DC components of these detectors in a number of practically important cases of boiling anomaly. It is shown that the noise component of the available neutron detector signals can be used for the detection of boiling in these cases. Experiments have been carried out at a boiling setup in the research reactor HOR of the Interfaculty Reactor Institute, Technical University of Delft, The Netherlands. (author). 8 refs., 11 figs

Availability note (English)

MF available from INIS under the Report Number; Also available from Netherlands Energy Research Foundation, Library-ECN, P.O.Box 1, 1755 ZG Petten (NL).

Files

24038691.pdf

Files (271.1 kB)

Name Size Download all
md5:1af18a361235bfc47f7508377a7ca6be
271.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
ECN-RX--92-068

Conference

Title
15. International Meeting on Reduced Enrichment for Research and Test Reactors.
Dates
27 Sep - 1 Oct 1992.
Place
Roskilde (Denmark).