Evaluation of working air quality by using semipermeable membrane devices

  • 1. Analytical Chemistry Department, University of Valencia, Edifici Jeroni Munoz, 50 Dr. Moliner, 46100 Burjassot, Valencia (Spain)

Description

It has been evaluated the use of semipermeable membrane devices (SPMDs) as passive samplers of organophosphorus pesticides from air, in order to determine the contamination of working environments. Additionally, the use of SPMDs as portable samplers has been also considered. The analytical methodology for the determination of diazinon, chlorpyrifos-methyl, pirimiphos-methyl, chlorpyrifos and fenthion in SPMDs exposed to contaminated air was based on microwave-assisted extraction and gas chromatography with mass spectrometry determination. Limit of detection (LOD) values from 2 to 4 ng SPMD-1 and repeatability from 2 to 7% were obtained by using the aforementioned methodology. Theoretical calculated sampling rates were employed for the estimation of the pesticide concentration in air, by using the pesticide mass retained in the deployed SPMD. The obtained LOD values, for a sampling time of 7 days, were from 1 to 2 ng m-3. The evaluation of the air quality of a pesticide laboratory with an intensive use of diazinon and chlorpyrifos has been made in order to check the operation safety conditions

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2008.07.039

Additional details

Identifiers

DOI
10.1016/j.aca.2008.07.039;
PII
S0003-2670(08)01356-1;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
626
Journal Issue
1
Journal Page Range
p. 21-27
ISSN
0003-2670
CODEN
ACACAM

Optional Information

Copyright
Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.