Published October 1990 | Version v1
Journal article

Ion temperature analysis of implosions of DT-filled capsules

  • 1. Lawrence Livermore National Laboratory, Livermore, California 94550 (USA)

Description

Fuel ion temperatures have been deduced for a series of implosions of defiled capsules by measuring the thermally broadened neutron time-of-flight signals at 10 and 20 m from the target. Typical temperatures were around 1 keV, and the corresponding thermal broadening was comparable to or less than the time response of the detectors. Under these conditions, error minimization is crucial, and we find that the location of the detector and the analysis technique are important. An optimum location exists, but is very sensitive to the yield of the implosion and to the detector response

Additional details

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
61
Journal Issue
10
Series
Rev. Sci. Instrum.
Journal Page Range
3128-3130
ISSN
0034-6748
CODEN
RSINA