Published February 1984 | Version v1
Report

Radiation levels in a gaseous diffusion plant assuming a low-enriched criticality event corresponding to the ANSI-standard minimum accident of concern

Description

The two-dimensional DOT-IV discrete-ordinates program was applied in analyses of the K-33 cell floor radiation levels due to four hypothetical criticality events. The radiation sources correspond to leakage spectra from critical uranyl fluoride solutions ranging from 1.2 to 4.95 weight percent enrichment. For the criticality-alarm-system ANSI Standard 8.3 minimum accident of concern (1200 Rad/hour at 2 meters from the surface of the critical volume), the dose rates at the maximum source-detector distance vary from approximately 150 to 200 mRad/hour of either neutron or photon radiation. The report includes a discussion of the methodology employed in the study, biological dose rates, thermal neutron reaction rates and appended dose rate plots. 10 references, 15 figures, 7 tables

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 as DE84007681.

Additional details

Publishing Information

Imprint Pagination
50 p.
Report number
K/CSD/TM--55