Temperature measurement in a high pressure dielectric barrier discharge using pressure induced line broadening and frequency shift

  • 1. Air Force Research Laboratory, WPAFB, Ohio 45433-7919 (United States)

Description

We have demonstrated two gas temperature measurement methods which are applicable to high pressure discharges where the pressure induced line broadening and frequency shift dominate over thermal broadening of atomic transitions. We have used diode-laser absorption spectroscopic measurements of argon 1s3→2p2 transition Doppler linewidth, Lorentzian broadening, and frequency shift to measure gas temperature in a dielectric barrier discharge operating from 5 up to 500 Torr with temperature rise less than 100 K

Additional details

Identifiers

Publishing Information

Journal Title
Applied Physics Letters
Journal Volume
88
Journal Issue
13
Journal Page Range
p. 131501-131501.3
ISSN
0003-6951
CODEN
APPLAB

Optional Information

Notes
(c) 2006 American Institute of Physics