Published 1983 | Version v1
Miscellaneous

On the problems of determining the Gα level in water and sediment samples

  • 1. Bundesanstalt fuer Gewaesserkunde, Koblenz (Germany, F.R.)

Description

In order to reduce the effect of energy dependence of the α counts and the effect of matrices, the samples should be measured with a constant and very small density (3.2 mg/cm2). Am-241 is used for calibration instead of the normally used calibration substance Usub(nat) in the form of UO2 Ac22H2O. One need not worry about problems of preparation. (DG)

Availability note (English)

Copy held by Fachinformationszentrum Energie, Physik, Mathematik G.m.b.H., Eggenstein-Leopoldshafen (Germany, F.R.).

Abstract (German)

Zur Reduzierung des Einflusses der Energieabhaengigkeit der α-Zaehlausbeute sowie des Matrixeinflusses sollten die Proben bei konstanter und moeglichst geringer Schichtdicke gemessen werden (3,2 mg/cm2). An Stelle der verwendeten Eichsubstanz Usub(nat) in Form von UO2Ac22H2O wird Am-241 zur Kalibrierung benutzt. Praeparationsprobleme sind nicht zu befuerchten. (DG)

Additional details

Additional titles

Original title (German)
Zur Problematik der Gα-Bestimmung an Wasser- oder Sedimentproben

Publishing Information

Imprint Title
Environmental radioactivity monitoring. Selected methods of monitoring radioactivity in the environment
Imprint Pagination
400 p.
Journal Page Range
p. 251-268.

Conference

Title
5. experts' discussion on monitoring of environmental radioactivity.
Dates
22-24 Mar 1983.
Place
Karlsruhe (Germany, F.R.).

Optional Information

Notes
Imprint:Ueberwachung der Umweltradioaktivitaet. Ausgewaehlte Verfahren zur Radioaktivitaetsueberwachung.;Vortraege.