Published May 1984 | Version v1
Report Open

Heavy ion injector for the CERN Linac 1

Description

An injector system has been designed to provide a fully stripped oxygen beam for acceleration in the CERN PS complex. An ECR source will provide an O6+ beam to a heavy ion RFQ accelerator. The beam from the RFQ will be further accelerated by the CERN Linac 1 (Old Linac) in the 2 β lambda-mode to an energy of 12.5 MeV/u at which point it will be fully stripped for subsequent acceleration in the CERN synchrotrons. The specifications of the new equipment and modifications to the existing linear accelerator are described

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02; 3 as DE85001644.

Files

16064466.pdf

Files (177.4 kB)

Name Size Download all
md5:c965425327981c3dccf028ccfbf8a7db
177.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
LBL--17165

Conference

Title
Linear accelerator conference.
Dates
7-11 May 1984.
Place
Darmstadt-Seeheim (Germany, F.R.).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16064466
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM INJECTION; CERN LINAC; HEAVY ION ACCELERATORS; MEV RANGE 10-100; QUADRUPOLE LINACS; SPECIFICATIONS
Descriptors DEC
ACCELERATORS; ENERGY RANGE; LINEAR ACCELERATORS; MEV RANGE

Optional Information

Secondary number(s)
CONF-840529--44.