Personnel neutron dosimetry applications of track-size distributions on electrochemically etched CR-39 foils

Description

The track-size distribution on electrochemically etched CR-39 foils can be used to obtain some limited information on the incident neutron spectra. Track-size distributions on CR-39 foils can also be used to determine if the tracks were caused by neutrons or if they are merely background tracks (which have a significantly different track-size distribution). Identifying and discarding the high-background foils reduces the number of foils that must be etched. This also lowers the detection limit of the dosimetry system. We have developed an image analyzer program that can more efficiently determine the track density and track-size distribution, as well as read the laser-cut identification numbers on each foil. This new image analyzer makes the routine application of track-size distributions on CR-39 foils feasible. 2 refs., 3 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE89001288.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
UCRL--98687

Conference

Title
2. conference on radiation protection and dosimetry.
Dates
31 Oct - 3 Nov 1988.
Place
Orlando, FL (USA).

INIS

Optional Information

Notes
Portions of this document are illegible in microfiche products.
Secondary number(s)
CONF-881032--2.