Published March 1, 2018 | Version v1
Journal article

Development and evaluation of a technique for in vivo monitoring of 60Co in human liver

  • 1. Instituto de Radioproteção e Dosimetria- IRD-CNEN (Brazil)

Description

60Co is an artificial radioactive metal produced by activation of iron with neutrons. It decays by beta particles and gamma radiation and represents a risk of internal exposure of workers involved in the maintenance of nuclear power reactors. Intakes can be quantified through in vivo monitoring. This work describes the development of a technique for the quantification of 60Co in human liver. The sensitivity of the method is evaluated based on the minimum detectable effective doses. The results allow to state that the technique is suitable either for monitoring of occupational exposures or evaluation of accidental intakes. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/975/1/012046

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
975
Journal Issue
1
Journal Page Range
[4 p.]
ISSN
1742-6596

Conference

Title
9. Brazilian Congress on Metrology
Acronym
Metrologia 2017
Dates
26-29 Nov 2017
Place
Fortaleza (Brazil)