Published September 2002 | Version v1
Journal article

Direct determination of lead at sub-ppb levels in secondary coolants of pressurized water reactor by electrothermal atomic absorption spectrometry with multiple injections

  • 1. Taiwan Power Company, Taipei, Taiwan (China). Power Research Institute, Chemistry Lab.

Description

The method of incorporating in-situ pre-concentration technique via multiple injections followed by electrothermal atomic absorption spectrometry (ETAAS) is described for the direct determination of lead at sub-ppb levels in secondary coolants of pressurized water reactor (PWR). Prior to ETAAS measurement, water samples were concentrated by means of multiple injections (9x90 μl) and evaporation in a pyrocoated graphite tube. Optimization of the in-situ pre-concentration via multiple injections with ETAAS analysis was investigated. The feasibility of the proposed method was tested for direct determination of lead in secondary coolants of pressurized water reactor. A SRM 1643c certified reference water sample has been used for quality control. The result are in good agreement with the certified value. By the use of 0.81 ml sample volume 0.012 ppb detection limit was obtained. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
253
Journal Issue
3
Journal Page Range
p. 357-360
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
8 refs.