Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT—Initial experience

  • 1. Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands)
  • 2. Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States)
  • 3. Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)
  • 4. Department of Radiology, Policlinico Universitario Campus Bio-Medico, Rome (Italy)
  • 5. Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

Description

Objective: To prospectively compare subjective and objective image quality in 20% tube current coronary CT angiography (cCTA) datasets between an iterative reconstruction algorithm (SAFIRE) and traditional filtered back projection (FBP). Materials and methods: Twenty patients underwent a prospectively ECG-triggered dual-step cCTA protocol using 2nd generation dual-source CT (DSCT). CT raw data was reconstructed using standard FBP at full-dose (Group1a) and 80% tube current reduced low-dose (Group1b). The low-dose raw data was additionally reconstructed using iterative raw data reconstruction (Group2). Attenuation and image noise were measured in three regions of interest and signal-to-noise-ratio (SNR) as well as contrast-to-noise-ratio (CNR) was calculated. Subjective diagnostic image quality was evaluated using a 4-point Likert scale. Results: Mean image noise of group2 was lowered by 22% on average when compared to group1b (p < 0.0001–0.0033), while there were no significant differences in mean attenuation within the same anatomical regions. The lower image noise resulted in significantly higher SNR and CNR ratios in group2 compared to group1b (p < 0.0001–0.0232). Subjective image quality of group2 (1.88 ± 0.63) was also rated significantly higher when compared to group1b (1.58 ± 0.63, p = 0.004). Conclusions: Image quality of 80% tube current reduced iteratively reconstructed cCTA raw data is significantly improved when compared to standard FBP and consequently may improve the diagnostic accuracy of cCTA

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2012.10.021

Additional details

Identifiers

DOI
10.1016/j.ejrad.2012.10.021;
PII
S0720-048X(12)00532-3;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
82
Journal Issue
2
Journal Page Range
p. 275-280
ISSN
0720-048X
CODEN
EJRADR

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.