Central axis depth dose for a 2.5 MV Van de Graaff generator

  • 1. Univ. of Oklahoma, Oklahoma City

Description

Central axis percentage depth dose values and isodose curves for the bremsstrahlung beam from a 2.5 MV Van de Graaff generator were measured with a water phantom at 100 cm target-to-surface distance. Tissue-air ratios were calculated from the central axis depth dose data. Use of the 2.5 MV percentage depth dose values are necessary for treatment planning since they are substantially larger than the values given in compilations for 2.0 MV beams

Additional details

Identifiers

Publishing Information

Journal Title
American Journal of Roentgenology
Journal Volume
126
Journal Issue
6
Series
Am. J. Roentgenol., Radium Ther. Nucl. Med.
Journal Page Range
1260-1265