Published February 2019 | Version v1
Journal article

Determination of the thermal neutron flux by measuring gamma radiations with high and low resolution detectors

  • 1. Department of Studies in Physics, Karnatak University, Dharwad (India)

Description

Thermal neutron flux (Φth) of Americium-Beryllium (Am-Be) neutron source has been measured by adopting the foil activation method. The neutrons emitted from Am-Be source are used to activate the Indium-115 (115In) foil. The gamma radiations emitted from the activated isomer 116m1In are measured with NaI(Tl) and HPGe detectors. The thermal neutron flux is measured by adopting the cadmium (Cd) foil difference technique in which the Cd foil placed in front of the source to prevent the thermal neutrons from entering into the indium foil. The neutron flux is determined by measuring the gamma radiation emitted from indium foil using a low and high energy resolution NaI(Tl) and HPGe detectors respectively. The measured thermal neutron flux obtained from both detectors has been compared and found that the Φth does not depend on the resolution and type of the detectors used in the present investigations. (author)

Availability note (English)

Available from https://jnp.chitkara.edu.in

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Nuclear Physics, Material Sciences, Radiation and Applications
Journal Volume
6
Journal Issue
2
Journal Page Range
p. 178-182