3D CAIPIRINHA SPACE versus standard 2D TSE for routine knee MRI: a large-scale interchangeability study
Creators
- 1. mVISION, Faculty of Medicine and Health Sciences, University of Antwerp, Universiteitsplein 1, 2610, Wilrijk, Antwerp (Belgium)
- 2. Department of Radiology, Antwerp University Hospital (UZA), Drie Eikenstraat 655, B-2650, Edegem (Belgium)
- 3. Imec-Vision Lab, Department of Physics, University of Antwerp, Universiteitsplein 1, 2610, Wilrijk, Antwerp (Belgium)
- 4. Clinical Trial Center (CTC), CRC Antwerp, Antwerp University Hospital, University of Antwerp, Drie Eikenstraat 655, 2650, Edegem (Belgium)
- 5. MOVANT, Faculty of Medicine and Health Sciences, University of Antwerp, Universiteitsplein 1, 2610, Wilrijk, Antwerp (Belgium)
Description
To perform a large-scale interchangeability study comparing 3D controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) TSE with standard 2D TSE for knee MRI. In this prospective study, 250 patients underwent 3 T knee MRI, including a multicontrast 3D CAIPIRINHA SPACE TSE (9:26 min) and a standard 2D TSE protocol (12:14 min). Thirty-three (13%) patients had previous anterior cruciate ligament and/or meniscus surgery. Two radiologists assessed MRIs for image quality and identified pathologies of menisci, ligaments, and cartilage by using a 4-point Likert scale according to the level of diagnostic confidence. Interchangeability of the protocols was tested under the same-reader scenario using a bootstrap percentile confidence interval. Interreader reliability and intermethod concordance were also evaluated. Despite higher image quality and diagnostic confidence for standard 2D TSE compared to 3D CAIPIRINHA SPACE TSE, the protocols were found interchangeable for diagnosing knee abnormalities, except for patellar (6.8% difference; 95% CI: 4.0, 9.6) and trochlear (3.6% difference; 95% CI: 0.8, 6.6) cartilage defects. The interreader reliability was substantial to almost perfect for 2D and 3D MRI (range κ, 0.785-1 and κ, 0.725-0.964, respectively). Intermethod concordance was almost perfect for all diagnoses (range κ, 0.817-0.986). Multicontrast 3D CAIPIRINHA SPACE TSE and standard 2D TSE protocols perform interchangeably for diagnosing knee abnormalities, except for patellofemoral cartilage defects. Despite the radiologist's preference for 2D TSE imaging, a pursuit towards time-saving 3D TSE knee MRI is justified for routine practice. Multicontrast 3D CAIPIRINHA SPACE and standard 2D TSE protocols perform interchangeably for diagnosing knee abnormalities, except for patellofemoral cartilage defects. Radiologists are more confident in diagnosing knee abnormalities on 2D TSE than on 3D CAIPIRINHA SPACE TSE MRI. Despite the radiologist's preference for 2D TSE, a pursuit towards accelerated 3D TSE knee MRI is justified for routine practice.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-022-08715-5Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 32
- Journal Issue
- 9
- Journal Page Range
- p. 6456-6467
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 53099241
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BONE JOINTS; CARTILAGE; COMPARATIVE EVALUATIONS; DATA COMPILATION; DIAGNOSIS; FEMUR; IMAGE PROCESSING; INTERCHANGEABILITY; LIGAMENTS; MALFORMATIONS; NMR IMAGING; PATHOLOGY; RELIABILITY; SURGERY; THREE-DIMENSIONAL CALCULATIONS; TIBIA
- Descriptors DEC
- ANIMAL TISSUES; BODY; CONNECTIVE TISSUE; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; EVALUATION; INFORMATION; MEDICINE; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; SKELETON