Published 1991 | Version v1
Report

A laser alignment system for low beta quadrupoles

  • 1. Fermi National Accelerator Lab., Batavia, IL (United States)

Description

The positions of the low beta quadrupoles in the B OE area of the Fermilab Tevatron were monitored using a laser based system. Two identical systems were used on either side of the collision point. The essential components of each system included a 2 mWatt helium neon laser, a set of lenses which could be remotely flipped into the laser beam, and a four quadrant silicon photocell detector. A computer system took the data remotely and stored the data in files for chronological comparisons. Mainly due to drifts in the laser the accuracy of the system was .5mm, but this was sufficient to check for long-term settling of the area around the collision pit

Additional details

Publishing Information

Imprint Title
Conference record of the 1991 IEEE particle accelerator conference: Accelerator science and technology. Volume 1 of 5
Imprint Pagination
689 p.
Journal Page Range
p. 631-633.
Report number
DOE/ER/40607--1-Vol.1

Conference

Title
1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC).
Dates
6-11 May 1991.
Place
San Francisco, CA (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
24002108
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Numerical Data, Non-conventional Literature
Descriptors DEI
ALIGNMENT; CALIBRATION; COLLIDING BEAMS; DATA ACQUISITION SYSTEMS; DATA ANALYSIS; EXPERIMENTAL DATA; FERMILAB COLLIDER DETECTOR; FERMILAB TEVATRON; LASER RADIATION; LASERS; LENSES; MAGNETS; POSITIONING; QUADRUPOLES
Descriptors DEC
ACCELERATORS; AMPLIFIERS; BEAMS; CYCLIC ACCELERATORS; DATA; ELECTROMAGNETIC RADIATION; EQUIPMENT; INFORMATION; MEASURING INSTRUMENTS; MULTIPOLES; NUMERICAL DATA; RADIATION DETECTORS; RADIATIONS; SYNCHROTRONS