Evaluation of the Elekta SymmetryTM 4D IGRT System by Using a Moving Lung Phantom

  • 1. The Catholic University of Korea, Incheon (Korea, Republic of)
  • 2. The Catholic University of Korea, Bucheon (Korea, Republic of)
  • 3. Kyonggi University of Korea, School of Medicine, Suwon (Korea, Republic of)
  • 4. Gyeong-Sang National University Hospital, Chinju (Korea, Republic of)
  • 5. The Catholic University of Korea, Seoul (Korea, Republic of)

Description

4D cone-beam computed tomography (CBCT) is a beneficial tool for the treatment of movable tumors because it can help us to understand where the tumors are actually located and it has a precise treatment plan. However, general CBCT images have a limitation in that they cannot perfectly perform a sophisticated registration. On the other hand, the SymmetryTM 4D image-guided radiation therapy (IGRT) system of Elekta offers a 4D CBCT registration option. In this study, we evaluated the usefulness of SymmetryTM. Planning CT images of the CIRS moving lung phantom were acquired 4D multi-detector CT (MDCT), and the images were sorted as 10 phases from 0% phase to 90% phase. The thickness of the CT images was 1 mm. Acquired MDCT images were transferred to the contouring software, and a virtual target was generated. A one-arc volumetric-modulated arc therapy (VMAT) plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified by using the XVI SymmetryTM system. The physical movement of the CIRS moving lung phantom was ±10.0 mm in the superiorinferior direction, ±1.0 mm in the lateral direction, and ±2.5 mm in the anterior-posterior direction. The movement of the phantom was measured from the 4D MDCT registration as ±10.2 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.45 mm in the anterior-posterior direction. The movement of the phantom was measured from the SymmetryTM registration as ±10.1 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.4 mm in the anterior-posterior direction. We confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors, and that the 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is the target of radiation treatment.

Additional details

Publishing Information

Journal Title
Journal of the Korean Physical Society
Journal Volume
67
Journal Issue
1
Series
11 refs, 3 figs, 1 tab
Journal Page Range
p. 260-263
ISSN
0374-4884

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
49069579
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; COMPUTERIZED TOMOGRAPHY; LUNGS; PERFORMANCE; PHANTOMS; RADIOTHERAPY; TOOLS; VERIFICATION
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; EQUIPMENT; MEDICINE; MOCKUP; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; STRUCTURAL MODELS; THERAPY; TOMOGRAPHY