Published 1995 | Version v1
Miscellaneous

Study on some performances of an array ion-chamber using EGS4 code

  • 1. Qinghua Univ., Beijing (China). Dept. of Engineering Physics

Description

The paper presents some Monte Carlo simulation results for an array ion-chamber applied in radiation imaging, including performances of wall effect, non-linearity feature of energy response, non-identity of real detection efficiency of every channel with the same unit, etc., part of simulation results have been compared with respective experiment data

Part of:
Proceedings of the 8th national conference on computer application in science and technology

Additional details

Publishing Information

Imprint Title
Proceedings of the 8th national conference on computer application in science and technology
Imprint Pagination
340 p.
Journal Page Range
p. 265-269.

Conference

Title
8. national conference on computer application in science and technology.
Dates
27 Oct - 1 Nov 1995.
Place
Huangshan (China).

Optional Information