Published April 2017 | Version v1
Journal article

Calculation of the maximum allowed ambient dose rate outside CT rooms to quantitatively assess the structural shielding performance

  • 1. Radiation Protection Division, Federal Office of Public Health, Bern (Switzerland)

Description

The goal of this study was to develop a method to quantitatively assess the structural shielding performance of computed tomography (CT) rooms in Switzerland. The method was based on the comparison between calculated maximum allowed ambient dose rate (DR) and measured ambient DR in adjacent spaces. If the measured DR exceeds the calculated maximum allowed value, additional shielding is required; otherwise the shielding is sufficient. The maximum allowed ambient DR was calculated using two different shielding concepts either based on the tube loading of the scanner or on the accumulated dose length product of the scans. The method was validated for 36 spiral CT head protocols. The average ratio of the maximum allowed ambient DR between both concepts was 1.11 (range 0.57-2.14). Among 36 CT rooms, 7 room boundaries were insufficiently shielded. In conclusion, this method allows the authority to check on-site the compliance of the structural shielding with legal requirements. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncw131

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
174
Journal Issue
2
Journal Page Range
p. 226-235
ISSN
0144-8420

Optional Information

Notes
13 refs.