Further considerations for damping in heavily insulated pipe systems
Description
Over the past several years a body of test data has been accumulated which demonstrates that damping in small diameter heavily insulated pipe systems is much larger than presently recommended by Regulatory Guide 1.61. This data is generally based on pipe systems using a stand-off insulation design with a heater annulus. Additional tests have how been completed on similar pipe systems using a strap-on insulation design without the heater annulus. Results indicate some reduction in damping over the stand-off designs. Test data has also been obtained on a larger sixteen-inch diameter heavily insulated pipe system. Results of these two additional test series are presented. Revised damping values for seismic design of heavily insulated pipe systems are then recommended
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE85008494.
Files
Additional details
Publishing Information
- Imprint Pagination
- 14 p.
- Report number
- HEDL-SA--3258-FP
Conference
- Title
- ASME pressure vessel and piping division conference.
- Dates
- 24-29 Jun 1985.
- Place
- New Orleans, LA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16086091
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DAMPING; FFTF REACTOR; LIQUID METAL COOLED REACTORS; LMFBR TYPE REACTORS; PIPES; SEISMIC EFFECTS; SPECIFICATIONS; SYSTEMS ANALYSIS; TESTING; THERMAL INSULATION
- Descriptors DEC
- BREEDER REACTORS; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; SODIUM COOLED REACTORS; TEST REACTORS
Optional Information
- Secondary number(s)
- CONF-850670--7.