Published January 4, 1985 | Version v1
Report Restricted

Further considerations for damping in heavily insulated pipe systems

Description

Over the past several years a body of test data has been accumulated which demonstrates that damping in small diameter heavily insulated pipe systems is much larger than presently recommended by Regulatory Guide 1.61. This data is generally based on pipe systems using a stand-off insulation design with a heater annulus. Additional tests have how been completed on similar pipe systems using a strap-on insulation design without the heater annulus. Results indicate some reduction in damping over the stand-off designs. Test data has also been obtained on a larger sixteen-inch diameter heavily insulated pipe system. Results of these two additional test series are presented. Revised damping values for seismic design of heavily insulated pipe systems are then recommended

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE85008494.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
HEDL-SA--3258-FP

Conference

Title
ASME pressure vessel and piping division conference.
Dates
24-29 Jun 1985.
Place
New Orleans, LA (USA).

INIS

Optional Information

Secondary number(s)
CONF-850670--7.