Published June 1994 | Version v1
Journal article

Ten MVA air-gap armature winding: Thermal, structural and dielectric results

  • 1. Massachusetts Inst. of Technology, Cambridge, MA (United States)

Description

This paper describes the armature winding built as part of MIT's 10 MVA superconducting generator project. The winding has a helical winding form, is an air-gap winding having no iron teeth in the active region, employs a limited voltage gradient insulation scheme and is cooled by an insulating fluid. Structurally, the winding employs bonded joints between the conductors and structural tubes, which are of filament-wound fiber-reinforced plastic. Preliminary tests indicated that thermal performance of this winding was satisfactory. On the other hand, the winding suffered a catastrophic insulation failure after only a short time at high voltage. The resulting fault gave the structural system of the armature winding (and the rest of the machine) a good test. In this paper the authors review the major aspects of the design of the winding, describe the thermal tests and then tell of the insulation failure. They can, at best, speculate about the cause of that failure, but they can, on the basis of this experience, make recommendations for further development of machines of this type

Additional details

Publishing Information

Journal Title
IEEE Transactions on Energy Conversion
Journal Volume
9
Journal Issue
2
Journal Page Range
p. 349-358.
ISSN
0885-8969
CODEN
ITCNE4

INIS