Radioactivity transport following steam generator tube rupture
Description
A review of the capabilities of the CITADEL computer code as well as plant experience to project radioactivity releases following a steam generator tube rupture in PWR's shows that certain experimental data are needed for reliable off-site dose predictions. This article defines five parameters which are the key for such predictions and discusses the functional dependence of these parameters on various operational variables. The above parameters can be used in conjunction with CITADEL or they can be inserted in the appropriate equations which then conveniently can be programmed as a subroutine in thermal-hydraulic system codes. A joint Westinghouse, Electric Power Research Institute and Nuclear Regulatory Commission Program aimed at obtaining the five parameters empirically is described
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 - GPO $3.75 as TI85901278.
Files
Additional details
Publishing Information
- Imprint Pagination
- 40 p.
- Report number
- NUREG--1108
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16078198
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- MULTI-PARAMETER ANALYSIS; PWR TYPE REACTORS; RADIOACTIVITY TRANSPORT; RUPTURES; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; ENRICHED URANIUM REACTORS; FAILURES; POWER REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS