The methodology and contents of improper of AP1000 human reliability analysis is improper, and it should be modified according to the comments of safety review. Based on the research of foreign document, combined with the specific design of passive nuclear power plant, the internal events human reliability analysis methodology and post-fire human reliability analysis methodology are obtained and systematic analysis is performed for generation III passive nuclear power plant to support the safety review. (authors)