High dose three-dimensional conformal boost (3DCB) using an orthogonal diagnostic X-ray set-up for patients with gynecological malignancy: a new application of real-time tumor-tracking system
Creators
- 1. Gynecology, Reproductive and Developmental Medicine, Division of Pathophysiological Science, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-Ku, Sapporo 060-8638 (Japan)
- 2. Department of Radiology, Hokkaido University Hospital, Sapporo (Japan)
Description
The feasibility and accuracy of high dose three-dimensional conformal boost (3DCB) using three internal fiducial markers and a two-orthogonal X-ray set-up of the real-time tumor-tracking system on patients with gynecological malignancy were investigated in 10 patients. The standard deviation of the distribution of systematic deviations (Σ) was reduced from 3.8, 4.6, and 4.9 mm in the manual set-up to 2.3, 2.3 and 2.7 mm in the set-up using the internal markers. The average standard deviation of the distribution of random deviations (σ) was reduced from 3.7, 5.0, and 4.5 mm in the manual set-up to 3.3, 3.0, and 4.2 mm in the marker set-up. The appropriate PTV margin was estimated to be 10.2, 12.8, and 12.9 mm in the manual set-up and 6.9, 6.7, and 8.3 mm in the gold marker set-up, respectively, using the formula 2Σ+0.7σ. Set-up of the patients with three markers and two fluoroscopy is useful to reduce PTV margin and perform 3DCB
Additional details
Identifiers
- DOI
- 10.1016/j.radonc.2004.08.006;
- PII
- S0167-8140(04)00359-7;
Publishing Information
- Journal Title
- Radiotherapy and Oncology
- Journal Volume
- 73
- Journal Issue
- 2
- Journal Page Range
- p. 219-222
- ISSN
- 0167-8140
- CODEN
- RAONDT
INIS
- Country of Publication
- Ireland
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 36074452
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; CARCINOMAS; ERRORS; FEMALE GENITALS; FLUOROSCOPY; IMAGES; MANUALS; PATIENTS; RADIATION DOSES; RADIOTHERAPY
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; BODY; DIAGNOSTIC TECHNIQUES; DISEASES; DOCUMENT TYPES; DOSES; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY
Optional Information
- Copyright
- Copyright (c) 2004 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.