Published November 1982 | Version v1
Report Open

Investigation of environmentally assisted fracture of metallic nuclear-waste-package barrier materials in simulated basalt repository environments

Description

Statically loaded corrosion tests, slow strain rate (SSR) tests, and fatigue crack growth rate (FCGR) tests were conducted to evaluate the relative susceptibility of two titanium-base nuclear waste package candidate structural barrier materials Ti-grade 2 and Ti-grade 12-to environmentally enhanced cracking in a simulated repository environment. Statically loaded corrosion tests were done in oxic basalt ground water at 2500C; SSR tests were done in oxic basalt ground water at 150, 250, and 3000C and in air at 20 and 2500C; and FCGR tests were done in basalt ground water, fluoride-ion-enhanced basalt ground water, high-purity water, and air at 900C. The following conclusions can be drawn: the general corrosion rate of statically loaded corrosion coupons was very low in a 3-mo test, and no pitting or cracking of the specimens was observed. Ti-grade 2 and Ti-grade 12 exhibited strain rate dependent ductility diminution in SSR tests. The ductility diminution was most severe in Ti-grade 2 at 3000C and in Ti-grade 12 at 2500C. For of Ti-grade 12 it was found to be highly orientation dependent. The ductility diminution was also found in tests conducted in air as well as in those conducted in the basalt ground water environment; however, the extent of the degradation was less in air. The ductility diminution cannot be attributed to stress corrosion cracking because the fracture mode was microvoid coalescence in all tests. Evidence obtained in the current study and correlation of the present results with results obtained by other researchers indicate that dynamic strain aging is responsible for the loss of ductility. The FCGR of Ti-grade 2 and Ti-grade 12 was not affected by any of the environmental conditions used in this study, which indicates that no environmental cracking mechanism is operative under the conditions tested (900C, oxic ground water, and frequencies from 0.01 to 5 Hz)

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 as DE83005126.

Files

14754162.pdf

Files (723.6 kB)

Name Size Download all
md5:8019f9ee911297327294ca1500575eeb
723.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
34 p.
Report number
PNL--4379