Published November 1978 | Version v1
Report Open

An experimental and analytical study of transient heat transfer in the region of dryout for a heated tube using freon-12 as coolant

Description

Sensitivity studies have shown that during the blowdown phase of a hypothetical loss-of-coolant accident (LOCA) in a pressurised water reactor (PWR), the maximum temperature predicted for the cladding of a nuclear fuel element is highly dependent on the heat transfer relationships assumed to describe the onset of dryout and the subsequent post-dryout heat transfer at the relevant coolant conditions. In the present work, power transient experiments were performed using vertical round tube test sections to determine the heat transfer characteristics associated with a change from pre-dryout to post-dryout flow boiling conditions. Because of the availability of rig and instrumentation, tests were conducted using Freon-12 as the coolant and electrically heated tubes as the heat dissipating surfaces

Availability note (English)

MF available from INIS under the Report Number.

Files

11500254.pdf

Files (1.1 MB)

Name Size Download all
md5:7a13fd3db65259109ab515fd52ee8a0c
1.1 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
61 p.
Report number
AAEC/E--452

Optional Information

Notes
32 refs.