Published December 1993
| Version v1
Journal article
Uranium fluorescence analysis in the raffinate solution of nuclear fuel conversion process using time-resolved laser-induced fluorimetry
- 1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)
Description
A simple and new uranium analysis technique for raffinate solution of nuclear fuel conversion process was developed using a time-resolved laser-induced fluorimetry. The addition of 4M-phosphoric acid more than 10 times in volume to the raffinate sample was found to be efficient for obtaining stable uranium fluorescence signal which was not influenced by many fluorescence quenchers. A calibration curve of a good linearity for the fluorescence intensity vs. the uranium concentration was obtained at the range of 3.0 x 10-6 - 6.0-5 M UO2+2 in the raffinate samples. (Author)
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Nuclear Society
- Journal Issue
- v.25 (4
- Journal Page Range
- p. 548-551.
- ISSN
- 0372-7327
- CODEN
- WJHKAW
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 25040084
- Subject category
- S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
- Descriptors DEI
- CHEMICAL COMPOSITION; CONCENTRATION RATIO; FLUORESCENCE; FLUORESCENCE SPECTROSCOPY; LASERS; NUCLEAR FUEL CONVERSION; PHOSPHORIC ACID; URANIUM; WASTE WATER
- Descriptors DEC
- ACTINIDES; AMPLIFIERS; ELEMENTS; EMISSION; EMISSION SPECTROSCOPY; EQUIPMENT; HYDROGEN COMPOUNDS; INORGANIC ACIDS; INORGANIC COMPOUNDS; LIQUID WASTES; LUMINESCENCE; METALS; OXYGEN COMPOUNDS; PHOSPHORUS COMPOUNDS; PHOTON EMISSION; SPECTROSCOPY; WASTES; WATER