Published September 2012 | Version v1
Journal article

Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS

  • 1. Office of Biospheric Assessment for Waste Disposal, National Institute of Radiological Sciences, 491 Anagawa, Chiba 263-8555 (Japan)
  • 2. Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori 036-8564 (Japan)

Description

We analyzed the activities of 239Pu, 240Pu, 239+240Pu, 241Pu, the ratio of number of atoms (atom ratio) for 240Pu/239Pu, and the activity ratio of 241Pu/239+240Pu in seawater reference materials, IAEA-443 and IAEA-381, using a highly sensitive isotope dilution sector field inductively coupled plasma mass spectrometry method. With a mean chemical yield of 65% determined with 242Pu as a tracer, we found that the experimentally established values in IAEA-443 for 239Pu, 240Pu, 241Pu and 239+240Pu activities are almost the same as those in IAEA-381. Regarding the 239+240Pu activity, we provided the most precise and accurate result among the twelve laboratories, which participated in the interlaboratory comparison. In addition, for the 240Pu/239Pu atom ratio, our results for IAEA-381 (0.2315±0.0008) and IAEA-443 (0.2325±0.0008) are in good agreement with the IAEA information value (0.229±0.006), but have much smaller uncertainty. Since the new seawater reference material, IAEA-443, is commercially available, it can be used not only for method validation for seawater plutonium isotope ratio and activity analysis, but also for more general use as a plutonium isotope standard for mass discrimination correction for other environmental samples. - Highlights: ► We analyzed Pu activities and isotopic compositions in two seawater reference materials. ► We provided the most precise and accurate result of 239+240Pu activity in IAEA-443 and IAEA-381. ► Precise and accurate Pu isotopic composition in IAEA-443 were provided. ► The new seawater reference material can be used for mass bias correction and method validation for Pu determination.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2012.02.049

Additional details

Identifiers

DOI
10.1016/j.apradiso.2012.02.049;
PII
S0969-8043(12)00097-8;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
70
Journal Issue
9
Journal Page Range
p. 1944-1948
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
18. international conference on radionuclide metrology and its applications
Dates
19-23 Sep 2011
Place
Tsukuba (Japan)

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.