Description

Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerologia, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with 137Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrologia, to known 137Cs gamma radiation air kerma. Radionuclides considered for this study are 131I, 18F, 67Ga, 99mTc, 111In, 201Tl and 137Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placed during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with 131I and 137Cs. High dose values were found at the waste storage room, outside corridor of 137Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the 137Cs brachytherapy corridor is equal to (18.51±0.02)x10-3 mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05±0.03)x10-3 mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
1310
Journal Issue
1
Journal Page Range
p. 35-38
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
11. Mexican symposium on medical physics
Dates
19-22 Mar 2010
Place
Mexico City (Mexico)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42099860
Subject category
S63: RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALARA; BRACHYTHERAPY; CALIBRATION; CESIUM 137; DOSE EQUIVALENTS; FLUORINE 18; GALLIUM 67; GAMMA CAMERAS; GAMMA RADIATION; INDIUM 111; INJECTION; IODINE 131; KEV RANGE 100-1000; PATIENTS; RADIATION DOSES; TECHNETIUM 99; THALLIUM 201; THERMOLUMINESCENCE; THERMOLUMINESCENT DOSEMETERS; WASTE STORAGE
Descriptors DEC
BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; CAMERAS; CESIUM ISOTOPES; DAYS LIVING RADIOISOTOPES; DOSEMETERS; DOSES; ELECTROMAGNETIC RADIATION; ELECTRON CAPTURE RADIOISOTOPES; EMISSION; ENERGY RANGE; FLUORINE ISOTOPES; GALLIUM ISOTOPES; HEAVY NUCLEI; HOURS LIVING RADIOISOTOPES; INDIUM ISOTOPES; INTAKE; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; IODINE ISOTOPES; IONIZING RADIATIONS; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; KEV RANGE; LIGHT NUCLEI; LUMINESCENCE; LUMINESCENT DOSEMETERS; MANAGEMENT; MEASURING INSTRUMENTS; MEDICINE; MINUTES LIVING RADIOISOTOPES; NANOSECONDS LIVING RADIOISOTOPES; NUCLEAR MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ODD-ODD NUCLEI; PHOTON EMISSION; RADIATIONS; RADIOISOTOPES; RADIOLOGY; RADIOTHERAPY; STORAGE; TECHNETIUM ISOTOPES; THALLIUM ISOTOPES; THERAPY; WASTE MANAGEMENT; YEARS LIVING RADIOISOTOPES

Optional Information

Notes
(c) 2010 American Institute of Physics