Receptor dose and patient dose in radiographic exposures - a 15 year review
- 1. Regional Radiation Protection Service, Royal Surrey County Hospital, Guildford (United Kingdom)
Description
A patient dose programme has been established locally for the last 15 years across 109 hospitals and 250 X-ray rooms in line with the National Protocol, in conjunction with a programme to look at routine performance of these rooms. Routine performance checks initially looked primarily at film density and AEC performance but with the introduction of Computerised Radiography (CR) across UK hospitals and a revision of recommended procedures in the UK, the emphasis has shifted to assessing receptor dose under AEC control. Results show a wide variation in film density in the early years indicating sub optimal performance and dose. The spread was reduced over later years. The introduction of CR has led to a variety of approaches by the CR companies, X-ray companies and local sites. Receptor doses vary widely as a result. Large variations within hospitals were also observed. The doses over the last 15 years are reviewed and compared against diagnostic reference levels and with the performance of the imaging chain. Results show that patient dose programmes and optimisation strategies were having an impact, but the introduction of CR requires renewed efforts to ensure images and doses are optimised. (author)
Additional details
Identifiers
Publishing Information
- Publisher
- IAEA
- Imprint Place
- Vienna (Austria)
- ISBN
- 978-92-0-105410-4
- Imprint Title
- Proceedings of IRPA12: 12. Congress of the International Radiation Protection Association: Strengthening Radiation Protection Worldwide - Highlights, Global Perspective and Future Trends
- Imprint Pagination
- vp.
- Series
- Proceedings Series
- Journal Page Range
- 8 p.
- ISSN
- 0074-1884
Conference
- Title
- 12. Congress of the International Radiation Protection Association: Strengthening Radiation Protection Worldwide - Highlights, Global Perspective and Future Trends
- Acronym
- IRPA12
- Dates
- 19-24 Oct 2008
- Place
- Buenos Aires (Argentina)
INIS
- Country of Publication
- Austria
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43011918
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSES; IMAGES; PATIENTS; RECEPTORS; REVIEWS; X RADIATION
- Descriptors DEC
- DOCUMENT TYPES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEMBRANE PROTEINS; ORGANIC COMPOUNDS; PROTEINS; RADIATIONS
Optional Information
- Notes
- 8 refs, 6 figs, 4 tabs Imprint:This CD-ROM is attached to the printed publication
- Secondary number(s)
- STI/PUB--1460 (Companion CD)