Calibration and performance of a real-time gamma-ray spectrometry water monitor using a LaBr3(Ce) detector
Creators
- 1. Unitat de Física Mèdica, Facultat de Medicina i Ciències de la Salut, Universitat Rovira i Virgili, Reus, Tarragona, ES-43201 (Spain)
Description
Highlights: • A 2″ × 2″ LaBr3(Ce) gamma-ray spectrometry water monitor is characterized. • Experimental energy and resolution calibrations are performed. • The detector efficiency is obtained by MC simulations with EGS5 code system. • Minimum detectable activity concentrations for 131I and 137Cs are given. • A rainfall radiological increment is compared with the NaI(Tl) monitor. - Abstract: A scintillation gamma-ray spectrometry water monitor with a 2″ × 2″ LaBr3(Ce) detector was characterized in this study. This monitor measures gamma-ray spectra of river water. Energy and resolution calibrations were performed experimentally, whereas the detector efficiency was determined using Monte Carlo simulations with EGS5 code system. Values of the minimum detectable activity concentrations for 131I and 137Cs were calculated for different integration times. As an example of the monitor performance after calibration, a radiological increment during a rainfall episode was studied.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radphyschem.2017.10.008Additional details
Identifiers
- DOI
- 10.1016/j.radphyschem.2017.10.008;
- PII
- S0969806X17306369;
Publishing Information
- Journal Title
- Radiation Physics and Chemistry (1993)
- Journal Volume
- 144
- Journal Page Range
- p. 444-450
- ISSN
- 0969-806X
- CODEN
- RPCHDM
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 50080168
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S38: RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR CHEMISTRY;
- Descriptors DEI
- CALIBRATION; CESIUM 137; COMPUTERIZED SIMULATION; GAMMA RADIATION; GAMMA SPECTROSCOPY; IODINE 131; LANTHANUM BROMIDES; MONTE CARLO METHOD; NAI DETECTORS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BROMIDES; BROMINE COMPOUNDS; CALCULATION METHODS; CESIUM ISOTOPES; DAYS LIVING RADIOISOTOPES; ELECTROMAGNETIC RADIATION; HALIDES; HALOGEN COMPOUNDS; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; IONIZING RADIATIONS; ISOTOPES; LANTHANUM COMPOUNDS; LANTHANUM HALIDES; MEASURING INSTRUMENTS; NUCLEI; ODD-EVEN NUCLEI; RADIATION DETECTORS; RADIATIONS; RADIOISOTOPES; RARE EARTH COMPOUNDS; SCINTILLATION COUNTERS; SIMULATION; SOLID SCINTILLATION DETECTORS; SPECTROSCOPY; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- © 2017 Elsevier Ltd. All rights reserved.